您好 ,  歡迎來到59598晟江工業品 登錄后可利用更多便捷功能 會員中心  | 新會員注冊 [退出]
  • 已選總價:¥0.00
  • 已選數量:0件
所有費用均已包含增值稅,不含運費。運費詳情請參閱運費指導書。
產品詳情與編號
序號 產品編號 名稱 Weight Accessories pressure gauges Recommended container volume [LTR] Pressure gauge connection Connection thread Flow capacity* [l/min] Outlet pressure max. [bar] Gear ration max. 售價 訂購數量
 
任何
整體
全部的
其他
都是
整體
完全
所有的
   
1.0 DUE 1900 A 9kg / pc. MW 1640 50 - 100 R 1/8" G 1/2" 1.900 2 - 10 2 : 1 ¥14933.36
2.0 DUE 60 A 900g / pc. MW 2527 1.3 - 3 R 1/8" G 1/4" 60 2 - 20 4 : 1 ¥4421.36
3.0 DUE 1600 A 9kg / pc. MW 2540 30 - 50 R 1/8" G 1/2" 1.600 2 - 16 2 : 1 ¥15898.08
4.0 DUE 230 A 850g / pc. MW 2527 10 - 12 R 1/8" G 1/4" 230 2 - 20 2 : 1 ¥4826.72
5.0 DUE 1000 A 3.6kg / pc. MW 1640 20 - 25 R 1/8" G 3/8" 1.000 2 - 10 2 : 1 ¥9223.92
注:本公司對上述參數保有最終解釋權,如若變動,恕不通知。
Pneumatic pressure booster, up to 20 bar

Application: The pressure booster increases the input pressure to the value set on the control valve. The outlet pressure can measure max. four or. 2two times the input pressure, but can never exceed the max. outlet pressure. Should an individual consumer (clamping cylinder etc.) be operated with a pressure higher than the standard network pressure, the pressure booster can accordingly increase the supply pressure for this single consumer. An installed pressure regulator maintains a constant working pressure (with less pulsation).
Advantages: High energy saving and no electrical energy necessary directly on consumer. For a further consumer, it is not necessary to pretension the entire compressed air network to a higher level.
Installation recommendation: In order to reduce the pressure pulsation on the secondary side, we recommend creating an additional volume in the form of a container. If the volume of the serially connected air duct is insufficient, we recommend the container volumes given in the table.
Media: Filtered, unoiled compressed air
Installation position: horizontal
Temperature range: +5°C to max. +50°C
Warning: Order accessories at the same time! Please order silencers and pressure gauges separately!
*measured at 5 bar input and outlet pressure. Please note: The greater the pressure increase of P1 to secondary P2 set at the regulator, the lower the available volume flow rate, such.as. the DUE 230 A achieves a 100 litre per second supply amount at 8 bar outlet pressure if the input pressure is 5 bar. We would be happy to provide you with the flow-rate characteristics if needed.
Catalogue page Pneumatic Atlas 8 (Page 573) Technical documentation
All technical data are to be understood as non-binding reference values. prices given plus VAT
Click here in order to show prices with VAT included.
Copyright ©2012 SME Corporation All Rights Reserved
ICP備案證書號:··
???????|??????|??????|??????|???????
欧美一区二区日韩一区二区_欧美日本一道高清二区三区_老司机在线精品视频免费看_欧美日韩国产高清视频 欧美一区二区日韩一区二区_欧美日本一道高清二区三区_老司机在线精品视频免费看_欧美成在线视频 欧美一区二区日韩一区二区_欧美日本一道高清二区三区_老司机在线精品视频免费看_欧美伦理一区二区三区

653--------m.xyzpass.cn

525--------m.dft.net.cn

408--------m.vrbaxr.cn

430--------m.smpx.net.cn

934--------m.kqcz.com.cn

562--------m.asalink.cn

306--------m.jnym.com.cn

621--------m.whab.com.cn

359--------m.wtianx.com.cn

742--------m.998385.cn